The Flocare Infinity Pump is a state-of-the-art device designed for enteral feeding, providing a reliable and efficient solution for individuals who require nutritional support through feeding tubes. Whether you’re a patient, caregiver, or healthcare professional, mastering the use of this pump is essential for ensuring a smooth and safe feeding experience. With its user-friendly interface, customizable feeding options, and portable design, the Flocare Infinity Pump simplifies the process of administering enteral nutrition, allowing for greater flexibility and independence. In this guide, we’ll walk you through the essential steps to effectively set up and use the Flocare Infinity Pump, helping you maximize its features while ensuring optimal care.
How to Use the Flocare Infinity Pump: A Comprehensive Guide
The Flocare Infinity Pump is a versatile and user-friendly device designed for enteral feeding. Whether you’re a caregiver or a patient managing nutrition through a feeding tube, understanding how to use this pump effectively is essential for ensuring a smooth and safe feeding experience. In this blog, we’ll walk you through the steps to use the Flocare Infinity Pump, along with some tips for optimal operation.
What is the Flocare Infinity Pump?
The Flocare Infinity Pump is a portable feeding device that allows for precise control over enteral nutrition delivery. It features an easy-to-read display, programmable settings, and various feeding options, making it suitable for both adults and children.
What are the Features of Flocare Infinity Pump?
The Nutricia Flocare Infinity Pump is designed for enteral feeding, offering a range of features that enhance user experience, safety, and flexibility. Here are the standout features:
1. Compact and Portable Design: Lightweight and easy to carry, making it ideal for both home and on-the-go use.
2. User-Friendly Interface: The intuitive display and keypad allow for easy programming and monitoring of feeding settings.
3. Customizable Feeding Options: Supports continuous, intermittent, and bolus feeding modes to accommodate different nutritional needs.
4. Accurate Delivery: Ensures precise control over feeding rates and volumes, allowing for individualized nutrition plans.
5. Alarms and Alerts: Equipped with alarms for occlusions, low battery, and other alerts to ensure safe operation and timely intervention.
6. Large Capacity: Compatible with various feeding sets and bags, enabling the use of different formulas and volumes.
7. Battery-Powered: Offers long battery life for convenient use without being tethered to an outlet, ideal for travel or outpatient care.
8. Easy Maintenance: Designed for straightforward cleaning and maintenance, ensuring hygiene and reliability.
9. Programmable Settings: Allows users to save specific feeding protocols for easy recall, enhancing consistency in feeding routines.
10. Versatile Compatibility: Works with various enteral feeding products and formulas, making it adaptable for different patient needs.
These features make the Flocare Infinity Pump a reliable choice for enteral feeding, promoting safety and convenience for both patients and caregivers.
How to Set Flocare Infinity Pump?
1. Preparation
– Gather Supplies: Before using the pump, ensure you have all necessary supplies, including the feeding set, formula, and any syringes or other accessories needed.
– Wash Hands: Always start by washing your hands thoroughly to prevent contamination.
2. Setting Up the Pump
– Power On: Press the power button to turn on the Flocare Infinity Pump.
– Select Language: If prompted, choose your preferred language for the display.
3. Connecting the Feeding Set
– Attach the Feeding Set: Connect the feeding set to the pump according to the manufacturer’s instructions.
– Prime the Line: To remove air from the feeding set, hold the feeding bag upright and allow the formula to flow through the line until all air bubbles are eliminated.
4. Programming the Pump
– Set the Rate: Use the keypad to input the desired feeding rate (mL/hour) based on your healthcare provider’s recommendations.
– Set the Volume: Input the total volume of formula to be delivered during the feeding session.
– Select Feeding Mode: Choose between continuous or bolus feeding, depending on your specific needs.
5. Starting the Feeding
– Begin Feeding: Once everything is set, press the start button to initiate the feeding process. The display will show the progress of the feeding.
– Monitor the Pump: Keep an eye on the pump during feeding to ensure it is functioning correctly. Watch for any alarms or error messages.
6. After Feeding
– Stop the Pump: When the feeding is complete, press the stop button. Disconnect the feeding set carefully, following proper protocols.
– Clean Up: Discard any unused formula and clean the feeding set as recommended. Follow your healthcare provider’s guidance on how often to replace the feeding set.
7. Maintenance and Care
– Regular Cleaning: Clean the pump and accessories regularly according to the manufacturer’s instructions to ensure optimal performance.
– Check for Errors: Periodically check the pump for any error messages or alerts.
How to Lock a Flocare Infinity Pump?
Locking the Flocare Infinity Pump is an important feature that prevents accidental changes to the settings during use. Here’s how to do it:
Step-by-Step Instructions to Lock the Pump
1. Power On the Pump: Ensure the Flocare Infinity Pump is turned on.
2. Access the Lock Function: Press and hold the “Select” button for about three seconds until the lock icon appears on the display.
3. Confirmation: Once the lock icon is visible, the pump is locked. This means that any adjustments to the settings cannot be made until it is unlocked.
To Unlock the Pump
1. Press and Hold: Press and hold the “Select” button again for about three seconds.
2. Unlock Confirmation: The lock icon will disappear, indicating that the pump is now unlocked and can be adjusted.
Additional Tips
– Check the Manual: Always refer to the user manual for specific instructions related to your model.
– Keep It Secure: Locking the pump is particularly useful during transport or when care is being provided to avoid accidental changes.
By following these steps, you can easily lock and unlock the Flocare Infinity Pump, ensuring safe and effective use during enteral feeding.
How to Stop Flocare Infinity Pump?
Stopping the Flocare Infinity Pump correctly is essential to ensure safety and proper feeding management. Here’s a step-by-step guide on how to stop the pump:
Step-by-Step Instructions
1. Monitor the Feeding: Keep an eye on the pump display to see the current feeding status and volume remaining.
2. Press the Stop Button:
– Locate the “Stop” button on the pump. It’s typically marked clearly.
– Press the “Stop” button to halt the feeding process. This action will immediately stop the delivery of formula.
3. Check for Confirmation:
– The display may show a message indicating that the feeding has stopped, and the pump will cease all operations.
4. Disconnect the Feeding Set:
– After stopping the pump, carefully disconnect the feeding set from the pump’s port.
– Follow hygiene protocols when handling the feeding set.
5. Clean Up:
– Dispose of any unused formula according to guidelines.
– Clean the feeding set and pump as recommended by the manufacturer.
Important Notes
– Safety First: Always ensure that the pump is stopped before disconnecting the feeding set to avoid spills or leaks.
– Follow Care Guidelines: If you have specific instructions from your healthcare provider regarding stopping the pump, be sure to follow those.
By following these steps, you can safely stop the Flocare Infinity Pump after your feeding session.
Tips for Optimal Use
– Consult Your Healthcare Provider: Always follow your healthcare provider’s instructions regarding feeding rates and volumes.
– Stay Hydrated: Ensure that hydration is maintained as part of your nutritional care plan.
– Keep a Feeding Log: Consider keeping a log of feeding times, volumes, and any issues that arise. This can be helpful for follow-up appointments with your healthcare provider.
Where to Buy the Flocare Infinity Pump?
If you’re looking to purchase the Flocare Infinity Pump, Joya Medical Supplies is a trusted source that offers a range of medical products, including enteral feeding devices. By choosing Joya Medical Supplies, you can ensure that you’re getting the Flocare Infinity Pump and other essential products with confidence and ease.
Conclusion
The Flocare Infinity Pump is a reliable tool for delivering enteral nutrition, and mastering its use can greatly enhance the feeding experience for both patients and caregivers. By following this guide, you can ensure a safe, effective, and comfortable feeding process. If you have any further questions or concerns, don’t hesitate to reach out to your healthcare team for assistance.